Impulse ADAM-4053 User Manual Page 1

Browse online or download User Manual for Hardware Impulse ADAM-4053. Impulse ADAM-4053 User Manual [ru]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
www.advantech.com/products
Online Download
23-23
19
PC-based Controllers
Embedded Controllers
20
PAC
21
Motion Control
22
RS-485 I/O
23
Ethernet I/O
24
Building Automation
25
Self-service Terminals
26
eHome Platforms
27
ADAM-4053
ADAM-4055
ADAM-4080
Specifications
General
Connectors 2 x plug-in terminal blocks
(#14 ~ 22 AWG)
Power Consumption 1 W @ 24 V
DC
Watchdog Timer System (1.6 second)
Supported Protocols ASCII command
Digital Input
Channels 16
Input Level
Dry contact: Logic level 0: close to GND
Logic level 1: open
Wet contact: Logic level 0: 2 V max.
Logic level 1: 4 ~ 30 V
Effective Distance 500 m max.
(dry contact only)
Specifications
General
Connectors 2 x plug-in terminal blocks
(#14 ~ 28 AWG)
Power Consumption 1 W @ 24 V
DC
Watchdog Timer System (1.6 second) &
Communication
Supported Protocols ASCII command and
Modbus/RTU
Isolation Voltage 2,500 V
DC
LED Indicators Yes
Digital Input
Channels 8
Input Level
Dry Contact: Logic level 0: open
Logic level 1: close to GND
Wet Contact: Logic level 0: 3 V max.
Logic level 1: 10 ~ 50 V
Overvoltage 70 V
DC
Protection
Digital Output
Channels 8, open collector to 40 V
(200 mA max. load)
Power Dissipation Channel: 1 W max.
Total: 2.2 W (8 Channels)
ADAM-4053 ADAM-4055
16-ch Digital Input Module
16-ch Isolated Digital I/O Module with Modbus
2-ch Counter/Frequency Module
Common Specifications
General
Power Input Unregulated 10 ~ 30 V
DC
Environment
Humidity 5 ~ 95% RH
Operating -10 ~ 70°C
Temperature (14 ~ 158° F)
Storage Temperature -25 ~ 85°C
(-13 ~ 185° F)
ADAM-4080
Specifications
General
Connectors 2 x plug-in terminal blocks
(#14 ~ 22 AWG)
Power Consumption 2.0 W @ 24 V
DC
Watchdog Timer System (1.6 second)
Supported Protocols ASCII command
LED Indicators 5-digit readout, CH 0 or CH
1 (programmable)
Counter Input
Channels 2 independent counters
(32-bit + 1-bit overflow)
Input Frequency 50 kHz max.
Input Pulse Width >10 μs.
Input Mode lsolated or non-isolated
Isolated Input Level Logic level 0: 1 V max.
Logic level 1: 3.5~30 V
Isolation Voltage 2,500 V
RMS
Non-isolated Programmable
Input Level threshold:
Logic level 0: 0.8 Vmax.
Logic level 1: 2.4 ~ 5.0 V
Maximum Count 4,294,967,295 (32 bits)
Preset Type Absolute or relative
Programmable 2 μs ~ 65 ms
Digital Noise Filter
Alarm Alarm comparators on each
counter
Frequency 5 Hz ~ 50 kHz
Measurement Range
Programmable 1 or 0.1 second
Built-in Gate Time
Digital Output
Channels 2, open collector to 30 V,
30 mA max. load
Power Dissipation 300 mW for each channel
Ordering Information
ADAM-4053 16-ch Digital Input
Module
ADAM-4055 16-ch Isolated Digital I/O
Module with Modbus
ADAM-4080 2-ch Counter/Frequency
Modules
RoHS
COMPLIANT
2002/95/EC
RoHS
COMPLIANT
2002/95/EC
RoHS
COMPLIANT
2002/95/EC
Page view 0
1

Summary of Contents

Page 1 - ADAM-4080

www.advantech.com/productsOnline Download23-2319PC-based ControllersEmbedded Controllers20PAC21Motion Control22RS-485 I/O23Ethernet I/O24Building Auto

Related models: ADAM-4055 | ADAM-4080 |

Comments to this Manuals