www.sealevel.com PO Box 830 Liberty, SC 29657 864.843.4343 SIO4-104.2+2 User Manual Item Number 3544
© Sealevel Systems, Inc. - 8 - SIO4-104.2+2 User Manual Physical Installation Extreme care should be taken when installing the SIO4-104.2+2 to avoi
© Sealevel Systems, Inc. - 9 - SIO4-104.2+2 User Manual Physical Connection The port signals for the SIO4-104.2+2 are physically connected via a 40
© Sealevel Systems, Inc. - 10 - SIO4-104.2+2 User Manual Available for use with the SIO4-104.2+2 is the CA228, the CA110/CA143, and the CA222/TB10
© Sealevel Systems, Inc. - 11 - SIO4-104.2+2 User Manual If the CA143 is not used and the CA110 DB37 cable is used alone the following pin outs ap
© Sealevel Systems, Inc. - 12 - SIO4-104.2+2 User Manual Electrical Characteristics Specifications RS-232 Receiver Inputs • Voltage Range: ±15V
© Sealevel Systems, Inc. - 13 - SIO4-104.2+2 User Manual Appendix A - Troubleshooting Following these simple steps can eliminate most common proble
© Sealevel Systems, Inc. - 14 - SIO4-104.2+2 User Manual Appendix B - How To Get Assistance Begin by reading through the Troubleshooting Guide in A
© Sealevel Systems, Inc. - 15 - SIO4-104.2+2 User Manual Appendix C – Electrical Interface RS-232 Quite possibly the most widely used communication
© Sealevel Systems, Inc. - 16 - SIO4-104.2+2 User Manual Appendix D - Asynchronous Communications Serial data communications implies that individu
© Sealevel Systems, Inc. - 17 - SIO4-104.2+2 User Manual Appendix E – Silk Screen – 3544 PCB
© Sealevel Systems, Inc. SL9120 Revision 7/2006 SIO4-104.2+2 User Manual Table of Contents INTRODUCTION...
© Sealevel Systems, Inc. - 18 - SIO4-104.2+2 User Manual Warranty Sealevel's commitment to providing the best I/O solutions is reflected in t
© Sealevel Systems, Inc. SL9120 Revision 7/2006 - 1 - SIO4-104.2+2 User Manual Introduction SIO4-104.2+2 The SIO4-104.2+2, Item Number 3544, is a PC
© Sealevel Systems, Inc. - 2 - SIO4-104.2+2 User Manual Before You Get Started What’s Included The SIO4-104.2+2 is shipped with the following ite
© Sealevel Systems, Inc. - 3 - SIO4-104.2+2 User Manual Card Setup Address Selection The SIO4-104.2+2 occupies 16 consecutive I/O locations. The DI
© Sealevel Systems, Inc. - 4 - SIO4-104.2+2 User Manual Clock Modes The SIO4-104.2+2 utilizes a 14.7456 MHz oscillator. This is eight times faster
© Sealevel Systems, Inc. - 5 - SIO4-104.2+2 User Manual Electrical Interface Selection Each of the RS-422/485 ports on the SIO4-104.2+2 can be indi
© Sealevel Systems, Inc. - 6 - SIO4-104.2+2 User Manual Software Installation Windows 98/ME/2000/XP Installation 1. Start Windows. 2. Insert the S
© Sealevel Systems, Inc. - 7 - SIO4-104.2+2 User Manual installed, you can now look in Device Manager under Ports (COM & LPT) and each of the p